0800 161 56760800 161 5676

Euro Cash Register Ltd Unit 5 Bramery Business Park, Alstone Lane, Cheltenham, Gloucestershire, GL51 8HE, United Kingdom.

My Cart

Items:  items
Value: 

Order before 3pm for NEXT Working Day Delivery.

Sharp XE-A213 Help Videos

Keyboard Layout in Excel - Sharp XEA213

Keyboard Layout in Excel - Sharp XEA213

Fast download, just click "add to cart" and fill in your details.

Colour keyboard to easily setup your cash register.

Price: £4.99 (£5.99 Including VAT at 20%)

Sharp XE-A213 - How to install the journal take up spool




Sharp XE-A213 Instruction manual

Misc

XEA-213
Questions and Answers
Q. What is the size of the graphic logo?
A. Size: 288 dots (w) x 130 dots (h)
Color: black and white
Black Rate
- Total black rate: 35% or lower
- Local black rate: The black rate of a horizontal dot line is 55% or less.
Q. What size paper rolls are used on this model?
A. Paper roll: Width: 57.5 ± 0.5 mm
Max. diam.: 80 mm
Quality: High quality (0.06 to 0.08 mm thickness)
Q. What is the purpose of the USB port?
A. The USB is used when running the PC-Link software, this is a very basic programming tool
available from your supplier.
Q. Can you tell me how to take a Sales Reset report which contains only the Department
details?
A. It is not possible to take a report on the printer that contains departments only. There are
other Sharp ECR that can be purchased through our dealer network that can do this.
Q. Can you tell me how to turn the receipt OFF/ON
A. Enter the RCPT Key in the OP X/Z Position this will toggle the receipt from On to OFF
Q. Can you tell me how to program my XEA213 for copy receipt?
A. You have a key marked MA please insert this into the mode lock to start.
Turn the MA Key to the Z/PGM position.
Enter ST.
Enter 63, using the numeric buttons
Enter the X button.
Using the numeric buttons enter 01010001 (see page 68 Op Manual for complete table)
Enter ST.
Enter TL/NS to complete
Q. Can you tell me how to prevent my zero value PLU items being printed on the sales
reports
A. Your machine defaults to zero skip, see table below, however it may have been changed
Please note, it may be useful to refer to the Electronic
Version of both the User and Programming Manual.
Please use the Search function within Adobe Acrobat
You have a key marked MA please insert this into the mode lock to start.
Turn the MA Key to the PGM position.
Enter ST.
Enter 6, using the numeric buttons
Enter the X button.
Using the numeric buttons enter 11000111
Enter ST.
Enter TL/NS to complete
Return the MA key to the REG position to operate
Q. The sales figures are not resetting, they are continually accumulating.
A. To reset the various sales report the procedure is to Enter the . (decimal point) key before
the selected report, if the . (decimal point) key is not Entered the sales totals will not be
reset.
Example for Z1 General Report
Turn Key to X1/Z1
Press . (decimal point)
Press TL/NS
Q. Can I set Zero Skip in reports to save paper?
A. You have a key marked MA please insert this into the mode lock to start.
Turn the MA Key to the PGM position.
Enter ST.
Enter 6, using the numeric buttons
Enter the X button.
Using the numeric buttons enter 11000111
Enter ST.
Enter TL/NS to complete
Return the MA key to the REG position to operate
Q. Can you tell me how to program the rate for the VAT1.
A. You have a key marked MA insert this into the mode lock to start.
Turn the MA Key to the PGM position.
Enter ST
Enter 9, using the numeric buttons
Enter X
Enter 1 using the numeric buttons (Auto Vat rate)
Enter X
Enter 17.5
Enter ST
Enter TL to complete
Return the MA key to the REG position to operate
Q. Can you tell me how to delete a VAT1 rate
A. You have a key marked MA insert this into the mode lock to start.
Turn the MA Key to the PGM position.
Enter ST
Enter 9 (from the numeric buttons)
Enter X
Enter 1
Enter X
Enter
Enter TL/NS
Q. Can you tell me how to set my Department to be Auto VAT1.
A. You have a key marked MA insert this into the mode lock to start.
Turn the MA Key to the PGM position.
Enter Dept number (using Numeric Keys)
Press Dept #
Enter ST
Enter ST
Enter ST
Enter the <Actinic:Variable Name = '00'/> key to change to YES
Enter ST
Enter TL/NS
Return the MA key to the REG position to operate
Q. Can you tell me how to enter training mode and then cancel it afterwards?
A. You have a key marked MA please insert this into the mode lock to start.
Turn the MA Key to the PGM position.
Enter ST.
Enter 86, using the numeric buttons
Enter the X button.
Enter the chosen training Clerk Number (To cancel training clerk enter 0)
Enter ST.
Enter TL/NS to complete
Return the MA key to the REG position to operate
Q. Can you tell me how to prevent the REFUND button in REG position to operate
A. You have a key marked MA please insert this into the mode lock to start.
Turn the MA Key to the PGM position.
Enter ST.
Enter 5, using the numeric buttons
Enter the X button.
Enter 00000101, using the numeric buttons
Enter ST.
Enter TL/NS to complete.
Return the MA key to the REG position to operate
Q. Can you tell me how to make a PLU an open entry type?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press the PLU (required for programming).
Press ST
Press ST
Press ST
Using the numeric buttons press 00. (Until subdept appears).
Press ST
Press TL/NS to finish.
Q. Can you tell me how to program a preset price and name to a PLU?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press the PLU (to program).
Using the numeric buttons press 00
Using the text buttons enter the name.
Press ST.
Using the numeric buttons enter the price (without decimal point).
Press ST
Press TL/NS to finish.
Return the mode lock to the REG position.
Q. Can you tell me how to change a PLU key into a Department Key?
A. You have a key marked MA insert this into the Mode lock.
Turn the key to the PGM position.
Press the PLU key you wish to change
Press <Actinic:Variable Name = '00'/>
Enter text for Key Name
Press ST
Press ST
Enter Department Number
Press ST
Press <Actinic:Variable Name = '00'/> until SUBDEPT is shown on the display
Press ST
Press ST/TL
Q. Can you tell me how to program a name and price to a Department
A. You have a key marked MA insert this into the Mode lock.
Turn the key to the PGM position.
Press the DEPARTMENT button.
Using the numeric buttons enter the 00
Using the text buttons enter the name (max 12 characters).
Press ST.
Using the numeric buttons enter the price (without decimal point).
Press TL/NS to finish.
Return the mode lock to the REG position.
Q. Why does the error message OVER LIMIT appear when I press TL/NS?
You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Using the numeric buttons enter 0 0 8
Press the X button.
Press ST.
Press TL/NS to finish.
Return the mode lock to the REG position
Q. I am unable to use my register after the error message OVER LIMIT.
A. Turn to MGR Position
Finalise the current transaction by pressing the TL/NS key
Return the mode lock to the REG position
Q. Can you tell me how to change from receipt to journal printing?
A. You have a key marked MA, insert this into the Mode lock.
Turn the key to the PGM position.
Press ST.
Enter 6 (Using the numeric buttons)
Press the X button.
Using the numeric buttons enter 01000111
Press ST.
Press TL/NS to finish.
Return the mode lock to the REG position.
Q. Can you tell me how to change from Journal to Receipt printing?
A. You have a key marked MA, insert this into the Mode lock.
Turn the key to the PGM position.
Press ST.
Enter 6 (Using the numeric buttons)
Press the X button.
Using the numeric buttons enter 11000111
Press ST.
Press TL/NS to finish.
Return the mode lock to the REG position.
Q. Can you tell me how to program a clerk name?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press ST
Using the numeric buttons enter 5
Press the decimal point.
Using the numeric buttons enter the clerk number (1 - 25).
Press X button.
Using the alpha characters on the buttons enter the name (max 12 characters).
Press ST.
Press TL/NS to finish.
Return the mode lock to the REG position.
Q. Can you tell me how to Program a receipt logo message?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press ST
Using the numeric buttons enter 4
Press the decimal point.
Using the numeric buttons enter the line number (1 - 6).
Press X button.
Using the lettered buttons enter the text (max 24 characters). For Double size press DC first.
Press ST.
Repeat from line number until finished.
Press TL/NS to finish.
Return the mode lock to the REG position.
Q. Can you tell me how to set the time and date?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Using the numeric buttons enter the date (DDMMYYYY format)
for example 20th May 2007 = 20052007
Press ST
Using the numeric buttons enter the time (24hr format).
For example 5.30pm = 1730
Press ST to finish.
Return the mode lock to the REG position.
Q. I have INH, UNIT PR on the display
A. If this is when entry for department then perform the following:
Page 17 of User Manual
1. Turn to PGM
2. Enter the department number the customer is using for example 1 Dept#
3. Enter the ST key to skip the messages on display until Till shows DEPT-ENTRY-TYPE
appears
4. Now select the DEPT to be OPEN & PRESET
If it is PLU turn to page 23
As above but when the message ENTER PLU TYPE please select SUBDEPT
Q. What is the cable specification to connect my XEA-201 to my PC on
com1 or com2 only.
2------------------------3
3------------------------2
7------------------------1
1------------------------7
4------------------------6
6------------------------4
5------------------------5
Q. How do I program the AUTO key to perform £5 Cash?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press AUTO
Press 5
Press 00
Press TL/NS
Press AUTO
Press TL/NS
Turn key back to REG
Q. How do I print a PLU X Read report at the end of the day?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the X1/Z1 position.
Press PLU/SUB
Turn key to REG
Q. How do I print a PLU Z Resetting report at the end of the day?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the X1/Z1 position.
Press . (Decimal Point)
Press PLU/SUB
Turn key to REG
Q. How do I print a Clerk X Read Report?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the X1/Z1 position.
Press CLK#
Turn key to REG
Q. How do I print a Clerk Z Resetting Report?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the X1/Z1 position.
Press . (Decimal Point)
Press CLK#
Turn key to REG
Q. How do I reset the Electronic Journal?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the X1/Z1 position.
Press 700
Press . (Decimal Point)
Press TL/NS
Turn Key to REG
Q. How do I set the Currency symbol on receipts to £ instead of * ?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press ST
Enter 85
Enter . (Decimal Point)
Press SPACE
Press SPACE
Press SPACE
Enter 159
Press <Actinic:Variable Name = '00'/> Key
Press ST
Press TL/NS
Turn key to REG
Q. How can I set my GT’s (Grand Totals) to reset after every financial Z reading?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press ST
Enter 64
Enter X
Enter 00000010 (Using Numeric Keys)
Press ST
Press TL/NS
Turn key to REG
Q. Every time I turn the till on *MRS* is shown on the screen, how can I stop this?
A. This is most likely caused by the batteries failing or running flat. Please replace the 3 AA
Size batteries that are located under the printer hood.
Q. How can I set NO SALE to be disabled in REG mode?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press ST
Enter 5
Enter X
Enter 00000011
Press ST
Press TL
Turn Key to REG
Q. How do I prevent the Direct Void (Last Item Void) Key working in REG?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press ST
Enter 5
Enter X
Enter 00001001
Press ST
Press TL
Turn Key to REG
Q. How do I prevent the Indirect Void Key working in REG?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press ST
Enter 5
Enter X
Enter 00010001
Press ST
Press TL
Turn Key to REG
Q. How do I prevent Subtotal Voids working in REG?
A. You have a key marked MA insert this into the Mode lock.
Turn the mode lock to the PGM position.
Press ST
Enter 5
Enter X
Enter 00100001
Press ST
Press TL
Turn Key to REG

Recently Viewed